13 resultados para Zeros placement

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is proposed for determining the optimal placement and controller design for multiple distributed actuators to reduce the vibrations of flexible structures. In particular, application of piezoceramic patches to a horizontally-slewing single-link flexible manipulator modeled using the assumed modes method is investigated. The optimization method uses simulated annealing and allows placement of any number of distributed actuators of unequal length, although piezoceramics of fixed equal lengths are used in the example. It also designs an linear-quadratic-regulator controller as part of the optimization procedure. The measures of performance used in the investigation to determine optimality are the total mass of the system and the time integral of the absolute value of the hub and tip position error. This study also varies the relative weightings for each of these performance measures to observe the effects on the controller designs and piezoceramic patch positions in the optimized solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Fetal pulse oximetry (FPO) may improve the assessment of the fetal well-being in labour. Reports of health-care provider's evaluations of new technology are important in the overall evaluation of that technology. Aims: To determine doctors' and midwives' perceptions of their experience placing FPO sensors. Methods: We surveyed clinicians (midwives and doctors) following placement of a FPO sensor during the FOREMOST trial (multicentre randomised trial of fetal pulse oximetry). Clinicians rated ease of sensor placement (poor, fair, good and excellent). Potential influences on ease of sensor placement (staff category, prior experience in Birth Suite, prior experience in placing sensors, epidural analgesia, cervical dilatation and fetal station) were examined by ordinal regression. Results: There were 281 surveys returned for the 294 sensor placement attempts (response rate 96%). Sensors were placed by midwives (29%), research midwives (48%), registrars (22%) and obstetricians (1%). The majority of clinicians had 1 or more years' Birth Suite experience, had placed six or more sensors previously, and rated ease of sensor placement as good. Advancing fetal station (P < 0.001) and the presence of epidural analgesia prior to sensor placement (P = 0.029) predicted improved ease of sensor placement. Having a clinician placing a sensor for the first time predicted a lower rating for ease of sensor placement (P = 0.001), compared to having placed one or more sensors previously. Conclusions: Clinicians with varying levels of Birth Suite experience successfully placed fetal oxygen saturation sensors, with the majority rating ease of sensor placement as good.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Count data with excess zeros relative to a Poisson distribution are common in many biomedical applications. A popular approach to the analysis of such data is to use a zero-inflated Poisson (ZIP) regression model. Often, because of the hierarchical Study design or the data collection procedure, zero-inflation and lack of independence may occur simultaneously, which tender the standard ZIP model inadequate. To account for the preponderance of zero counts and the inherent correlation of observations, a class of multi-level ZIP regression model with random effects is presented. Model fitting is facilitated using an expectation-maximization algorithm, whereas variance components are estimated via residual maximum likelihood estimating equations. A score test for zero-inflation is also presented. The multi-level ZIP model is then generalized to cope with a more complex correlation structure. Application to the analysis of correlated count data from a longitudinal infant feeding study illustrates the usefulness of the approach.